| SITE ANALYSIS FORM - DOWNLOAD THE SITE ANALYSIS FORM | |||||
|
|
|||||
|
Get all of the Site Analysis and Permitting Info << click here >>
|
|||||
|
|
|
|
|
|
|
|
|
|
Interstate-80
SR 68, Trinity Dr. & North Point Dr.
|
|
62
|
62
|
|
|
Acres:
|
|
Sq. Ft:
|
|
Frontage:
|
|
Depth:
|
|
|
Building Style:
|
|
Maximum Height:
|
|
Orientation to:
|
|
|
Front:
|
|
Rear:
|
|
Sides:
|
|
|
Front:
|
|
Rear:
|
|
Sides:
|
|
|
Will there be any joint access or parking agreements? Describe: |
|
|
Curb Cuts: Number allowed and width:
|
|
Location and minimum spacing:
|
|
|
|
Minimum Number
|
RE Mgr.'s / Tenant Goal
|
Minimum Size
|
|
Standard Cars:
|
See Clarion County. Subdivision Ordinance
|
|
|
|
Handicapped:
|
Per state code
|
|
|
|
RV/Bus:
|
None
|
|
|
|
Pervious/Impervious Percentage:
|
Maximum 70% Impervious
|
Landscape Island Ratio:
|
NA |
|
North
|
|
|
South
|
|
|
East
|
|
|
West
|
|
|
Zoning:
|
None
|
City?
|
Monroe Twp
|
County?
|
Clarion
|
Building Code
|
Statewide Uniform Construction Code
|
|
Permitting Officials: Step 1Erosion & Sediment Control Plan Step 2Planning: Step 3 Building: Step 2 & 3 Should be submitted together. |
See DEP Northwest Regional Office 230 Chestnut Street Meadville, PA 16335-3481 Karl M. Gross, P.E. Sr. Civil Engineer Existing Permit No. PAG2061603005 County of Clarion, Department of Planning & Development Court House, 421 Main St. Clarion, PA 16214 Twila L. Rifenberrick, County Planner http://www.pamunicipalitiesinfo.com/counties/Clarion/monroe_twp/Info.htm |
Telephone: 814-332-6942 FAX #: 814-332-6121 Telephone: 814-226-4000 Ext. 2800 FAX #: 814-226-5275 E-mail: trifenberrick@co.clarion.pa.us Telephone: 814-745-2819 FAX #: 814-745-3182 E-mail: monroetwp@usachoice.net |
|
Permitting Steps:
|
Permitting Officials:
|
Official Contact Information:
|
Step 1Erosion |
DEP Northwest Regional Office 230 Chestnut Street Meadville, PA 16335-3481 Karl M. Gross, P.E. Sr. Civil Engineer Existing Permit No. PAG2061603005 |
Telephone: 814-332-6942 FAX #: 814-332-6121 |
Step 2Planning: |
County of Clarion, Department of Planning & Development Court House, 421 Main St. Clarion, PA 16214 Twila L. Rifenberrick, County Planner |
Telephone: 814-226-4000 Ext. 2800 FAX #: 814-226-5275 E-mail: trifenberrick@co.clarion.pa.us |
|
Step 3 Building: |
Township of Monroe |
Telephone: 814-745-2819 FAX #: 814-745-3182 E-mail: monroetwp@usachoice.net |
| Step 2 & 3 Should be submitted together. |
MISCELLANEOUS:
|
Any variance or rezoning issues?
|
All controls are from project DCR
|
|
|
Is subdivision required?
|
Per Clarion County Subdivision & Land Development Ordinance as part of Trinity Point.
|
|
|
Road Widening/Condemnations? (Include proposed interchange modifications/closures/relocations.)
|
Completed by developer
|
|
|
Other requirements per Code, Developer, or other Agency?
|
Department of Environmental Protection (DEP) for E&S control, Monroe Twp. Building permit and Trinity Point DCR.
|
|
|
Deed restrictions or covenants affecting property are Trinity Point DCR.
|
|
|
|
On Site Conditions - Existing improvements, billboards, tenants, general condition and topography:
|
Project is a master planned mixed-use park. Parcel sold to Tractor Supply; one under agreement with State of PA for regional communications center for PA State Police. Lot 14 planned for Clarion University Biotechnology Business Development Center.
|
|
|
Soils Testing: Is the site wooded, sparsely or heavily?
|
Rough graded per project drawings and master plan
|
|
|
Is the site sloped?
|
As shown on project drawings |
|
|
Is there any rock? How much & what size?
|
|
|
|
Are there any wetlands? |
No
|
|
|
Describe any conditions that would affect getting equipment on site to perform soils tests, surveys, and any other physical inspections: |
None
|
|
|
Utilities:
|
At property line?
|
Who extends?
|
Details
|
|
Electricity
|
Allegheny Power
|
|
|
|
Water
|
PA American Water Co.
|
|
|
|
Sanitary Sewer
|
Monroe Twp.
|
|
|
|
Natural Gas
|
National Fuel
|
|
|
|
Storm Sewer
|
Trinity Point approved plan.
|
|
|
|
On-site Retention?
|
Only temporary for E&S
|
|
As approved by DEP as addition to CTDC existing NPDES Permit No. PAG2061603005
|
|
Sign Style:
|
DCR Requirements:
|
|
||||||
|
|
Max. Height
|
Max. Sq. Foot
|
Number
|
|
||||
|
High Rise
|
35'
|
60 sf
|
1
|
|
||||
|
Building fascia
|
35'
|
60 sf
|
1
|
|
||||
|
Directional
|
Being designed
|
NA
|
2
|
|
||||
|
Off Premise
|
To be designed & permit
|
NA
|
1
|
|
||||
|
Do highway logo boards exist?
|
YES
|
Are any boards available:
|
YES
|
|
||||
|
What is State bumping policy for Logo Boards? Closest to interchange.
|
I-80 Available Boards:
Wolf Oil Co. 814-745-2001
Lamar Advertising 330-716-1944
|
|||||||
|
Workforce/Demographics | Business Support Links | Site Permitting | Contact Us |
|||